Calibration
Pressure,
Temperature,
Flow/Light/Sound,
Room Pressurization Test
We conduct Room Pressurization Test for industrial clean rooms. As a part of the validation process, this test verifies that a pressure differential meet the specified requirements.
Light Intensity Test
The purpose of the lighting level tests is to verify that the installed light levels and uniformity meet the specified requirements. We make use of modern testing instruments for assessment of lighting lux levels and intensity.
Noise Level Test
We perform noise level test that measure the sound pressure. The measurements will vary based on the occupancy state-of-the-art clean room. The purpose may vary but the procedures of testing are identical.
Air Exchange Rate
Air Exchange Rate tests determine the total air volume get in to the room within a clean room. The use of Testo Air Capture Hoods of Model No.Testo 420, assures accurate test results. The hood measures air volume flowing through registers, diffusers and grills. Weighing just 3.5 kgs, these air capture hoods are easy to use and carry. These hoods simply hold the accubalance up to a diffuser or grill and read direct supply or exhaust airflow on the large digital display.
Containment Test
We conduct Containment Tests for client's clean room facility. The test is carried to demonstrate that airborne contamination does not enter from a higher pressure area adjacent to the clean room by means of leaks in the construction materials. The test is conducted by trained and experienced technicians using modern instruments that assure accurate results.
Recovery Test
We execute recovery tests for clients across Industries. These tests demonstrate the ability of the clean room to remove particulate by purging the area with filtered air. It also testifies if the room can change from a "dirty" to "clean" state within the specified time. The test is conducted by experienced technicians from team. Our technicians have enriching experience and provide clients with high quality service. The ultimate goal of our company is to assure complete satisfaction of clients through effective execution of services and by providing best array of clean room equipment. We ensure that client's clean room facility is performing properly and accurately.
Temperature and Humidity Test
We conduct validation tests that include Temperature and Humidity Measurements / Tests. Two levels of temperature and humidity tests are used by us depending on the requirement. In the first level, general temperature and humidity uniformity are tested. The general level test is used to ensure that the clean room's HVAC system maintains the specified levels of temperature and humidity required for occupant comfort. The second level or the comprehensive level test identified that the clean room HVAC systems needs to maintain the specified levels of temperature and humidity required for both occupant comfort and process temperature control.